Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Biomed Opt ; 27(3)2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35324096

RESUMO

SIGNIFICANCE: Spatial frequency domain imaging (SFDI) is a wide-field diffuse optical imaging technique for separately quantifying tissue reduced scattering (µs ' ) and absorption (µa) coefficients at multiple wavelengths, providing wide potential utility for clinical applications such as burn wound characterization and cancer detection. However, measured µs ' and µa can be confounded by absorption from melanin in patients with highly pigmented skin. This issue arises because epidermal melanin is highly absorbing for visible wavelengths and standard homogeneous light-tissue interaction models do not properly account for this complexity. Tristimulus colorimetry (which quantifies pigmentation using the L * "lightness" parameter) can provide a point of comparison between µa, µs ' , and skin pigmentation. AIM: We systematically compare SFDI and colorimetry parameters to quantify confounding effects of pigmentation on measured skin µs ' and µa. We assess the correlation between SFDI and colorimetry parameters as a function of wavelength. APPROACH: µs ' and µa from the palm and ventral forearm were measured for 15 healthy subjects with a wide range of skin pigmentation levels (Fitzpatrick types I to VI) using a Reflect RS® (Modulim, Inc., Irvine, California) SFDI instrument (eight wavelengths, 471 to 851 nm). L * was measured using a Chroma Meter CR-400 (Konica Minolta Sensing, Inc., Tokyo). Linear correlation coefficients were calculated between L * and µs ' and between L * and µa at all wavelengths. RESULTS: For the ventral forearm, strong linear correlations between measured L * and µs ' values were observed at shorter wavelengths (R > 0.92 at ≤659 nm), where absorption from melanin confounded the measured µs ' . These correlations were weaker for the palm (R < 0.59 at ≤659 nm), which has less melanin than the forearm. Similar relationships were observed between L * and µa. CONCLUSIONS: We quantified the effects of epidermal melanin on skin µs ' and µa measured with SFDI. This information may help characterize and correct pigmentation-related inaccuracies in SFDI skin measurements.


Assuntos
Colorimetria , Pele , Epiderme , Humanos , Imagem Óptica/métodos , Pele/diagnóstico por imagem , Pigmentação da Pele
2.
Ann Plast Surg ; 87(4): 421-426, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34559711

RESUMO

BACKGROUND: Burns are devastating injuries, carry significant morbidity, and require long-term treatment or multiple reconstructive procedures. Wound healing and secondary insults caused by burn wound conversion are amendable to therapeutic intervention, where ischemia has been cited as one of the major factors (Dermatol Surg. 2008;34:1159-1169). Halting injury progression in the zone of stasis is crucial as conversion creates increased burn surface area and depth, leading to local and systemic consequences (J Burns Wounds. 2006;5:e2). Oxygen-carrying micro/nanobubbles, MNB(O2), offer a novel technology that can be used to effectively deliver oxygen to burn wounds and potentially counteract burn wound ischemia. METHODS: Topical irrigation with MNB(O2) of full-thickness burn wounds on a rodent model (n = 3) was compared against saline-treated controls (n = 3). Tissue structure (reduced scattering coefficient, µs'), oxyhemoglobin concentration (cHbO2), and tissue perfusion were quantified over the course of 28 days through spatial frequency domain imaging and laser speckle imaging. Histological samples taken at the end of the experiment were examined for evidence of wound healing. RESULTS: Findings in this preliminary study showed hastened healing with significant differences in spatial frequency domain imaging-measured µs' during wound healing (days 11-28) in MNB(O2) group. The healing "tipping point" seemed to occur at days 9 to 11 with increased collagen organization and increased cHbO2 occurring around that period confirming the gross healing improvements observed. In addition, histological evidence indicated that only the MNB(O2) burns had reached the remodeling phase by the end of 28-day study period. CONCLUSIONS: These preliminary findings propose the potential of MNB(O2) as a topical method for improving burn wound healing.


Assuntos
Queimaduras , Queimaduras/terapia , Humanos , Cicatrização
3.
J Biomed Opt ; 26(8)2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34387050

RESUMO

SIGNIFICANCE: Spatial frequency domain imaging (SFDI) is a wide-field imaging technique that provides quantitative maps of tissue optical properties. We describe a compact SFDI imager that employs a multispectral compound-eye camera. This design enables simultaneous image acquisition at multiple wavelengths. Such a device has potential for application for quantitative evaluation of superficial tissues by nonspecialists in low-resource settings. AIM: The aim of this work was to develop a compact SFDI imager for widefield imaging of in-vivo tissue optical properties and verify its ability to measure optical properties of tissue-simulating phantoms and in a preclinical model of burn wounds. APPROACH: This compound-eye imager was constructed using a CMOS sensor subdivided into multiple regions, each having a bandpass filter and objective lens. The ability of the instrument to image optical properties was compared with (1) a commercial SFDI imager and (2) a laboratory-based system. Initial validation of ability to accurately characterize optical properties was performed using a tissue-simulating optical phantom. It was then applied to an established murine model of thermal contact burn severity. In-vivo measurements of the optical properties of rat skin were performed before and after the application of burns. Histology was used to verify burn severity. RESULTS: Measurements of the tissue-simulating phantom optical properties made using the compound-eye imager agree with measurements made using the two comparison SFDI devices. For the murine burn model, the burns showed a decrease in the reduced scattering coefficient at all measurement wavelengths compared with preburn measurements at the same locations. This is consistent with previously reported changes in scattering that occur in full-thickness burns. CONCLUSION: We demonstrate the potential for SFDI to be translated into compact form factor using a compound-eye camera that is capable of obtaining multiple wavelengths channels simultaneously.


Assuntos
Queimaduras , Imagem Óptica , Animais , Queimaduras/diagnóstico por imagem , Estudos de Viabilidade , Camundongos , Imagens de Fantasmas , Ratos , Pele/diagnóstico por imagem
4.
J Biomed Opt ; 26(2)2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33569936

RESUMO

SIGNIFICANCE: Spatial frequency domain imaging (SFDI), a noncontact wide-field imaging technique using patterned illumination with multiple wavelengths, has been used to quantitatively measure structural and functional parameters of in vivo tissue. Using SFDI in a porcine model, we previously found that scattering changes in skin could potentially be used to noninvasively assess burn severity and monitor wound healing. Translating these findings to human subjects necessitates a better understanding of the variation in "baseline" human skin scattering properties across skin types and anatomical locations. AIM: Using SFDI, we aim to characterize the variation in the reduced scattering coefficient (µs') for skin across a range of pigmentation and anatomic sites (including common burn locations) for normal human subjects. These measurements are expected to characterize baseline human skin properties to inform our use of SFDI for clinical burn severity and wound healing assessments. APPROACH: SFDI was used to measure µs' in the visible- and near-infrared regime (471 to 851 nm) in 15 subjects at 10 anatomical locations. Subjects varied in age, gender, and Fitzpatrick skin type. RESULTS: For all anatomical locations, the coefficient of variation in measured µs' decreased with increasing wavelength. High intersubject variation in µs' at visible wavelengths coincided with large values of the melanin extinction coefficient at those wavelengths. At 851 nm, where intersubject variation in µs' was smallest for all anatomical locations and absorption from melanin is minimal, significant intrasubject differences in µs' were observed at the different anatomical locations. CONCLUSIONS: Our study is the first report of wide-field mapping of human skin scattering properties across multiple skin types and anatomical locations using SFDI. Measured µs' values varied notably between skin types at wavelengths where absorption from melanin was prominent. Additionally, µs' varied considerably across different anatomical locations at 851 nm, where the confounding effects from melanin absorption are minimized.


Assuntos
Queimaduras , Diagnóstico por Imagem , Animais , Humanos , Pele/diagnóstico por imagem , Suínos , Cicatrização
5.
Burns Open ; 4(2): 67-71, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32832745

RESUMO

While visual assessment by a clinician is the standard of care for burn severity evaluations, new technologies at various stages of development are attempting to add objectivity to this practice by quantifying burn severity. Assessment accuracy generally improves after the burn injury has progressed, but early assessments that correctly identify superficial partial and deep partial burns have the potential to lead to more prompt treatments and shorter recovery times. To date, Spatial Frequency Domain Imaging (SFDI) has only been used in animal models of burns, but has shown the potential to categorize burns accurately at earlier time points. Here we examine the potential for SFDI to assess burn severity in clinical patients. We also utilize Laser Speckle Imaging (LSI), an FDA cleared non-invasive imaging technology that typically measures blood perfusion in order to evaluate burns in clinical patients. We present a case series of two patients, both with partial thickness burns of varying severity. Partial thickness burns are often difficult for clinicians to categorize based on visual appearance alone. SFDI and LSI were both performed on each patient at approximately 24 and 72 h after their respective burn incidents. Each technique was able to render spatially resolved information that enabled improved assessment accuracy for each burn. This represents the first publication of SFDI applied to clinical burn patients after being successfully utilized in animal models, and highlights the potential for SFDI as a feasible tool for the timely categorization of burn severity.

6.
J Biomed Opt ; 24(11): 1-7, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31777223

RESUMO

Transplantation of kidneys results in delayed graft function in as many as 40% of cases. During the organ transplantation process, donor kidneys undergo a period of cold ischemic time (CIT), where the organ is preserved with a cold storage solution to maintain tissue viability. Some complications observed after grafting may be due to damage sustained to the kidney during CIT. However, the effects due to this damage are not apparent until well after transplant surgery has concluded. To this end, we have used spatial frequency domain imaging (SFDI) to measure spatially resolved optical properties of porcine kidneys over the course of 80-h CIT. During this time, we observed an increase in both reduced scattering (µs&') and absorption (µa) coefficients. The measured scattering b parameter increased until 24 h of CIT, then returned toward baseline during the remaining duration of the imaging sequence. These results show that the optical properties of kidney tissue change with increasing CIT and suggest that continued investigation into the application of SFDI to kidneys under CIT may lead to the development of a noninvasive method for assessing graft viability.


Assuntos
Isquemia Fria , Rim/diagnóstico por imagem , Imagem Óptica , Preservação de Órgãos , Animais , Biópsia , Temperatura Baixa , Cor , Processamento de Imagem Assistida por Computador , Óptica e Fotônica , Espalhamento de Radiação , Suínos
7.
J Biomed Opt ; 24(7): 1-9, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31313538

RESUMO

There is a need for noninvasive, quantitative methods to characterize wound healing in the context of longitudinal investigations related to regenerative medicine. Such tools have the potential to inform the assessment of wound status and healing progression and aid the development of new treatments. We employed spatial frequency domain imaging (SFDI) to characterize the changes in optical properties of tissue during wound healing progression in a porcine model of split-thickness skin grafts and also in a model of burn wound healing with no graft intervention. Changes in the reduced scattering coefficient measured using SFDI correlated with structural changes reported by histology of biopsies taken concurrently. SFDI was able to measure spatial inhomogeneity in the wounds and predicted heterogeneous healing. In addition, we were able to visualize differences in healing rate, depending on whether a wound was debrided and grafted, versus not debrided and left to heal without intervention apart from topical burn wound care. Changes in the concentration of oxy- and deoxyhemoglobin were also quantified, giving insight into hemodynamic changes during healing.


Assuntos
Queimaduras/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Óptica/métodos , Pele/diagnóstico por imagem , Transplantes/diagnóstico por imagem , Animais , Feminino , Transplante de Pele , Suínos , Cicatrização/fisiologia
8.
J Biomed Opt ; 24(5): 1-9, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31134769

RESUMO

Accurate assessment of burn severity is critical for wound care and the course of treatment. Delays in classification translate to delays in burn management, increasing the risk of scarring and infection. To this end, numerous imaging techniques have been used to examine tissue properties to infer burn severity. Spatial frequency-domain imaging (SFDI) has also been used to characterize burns based on the relationships between histologic observations and changes in tissue properties. Recently, machine learning has been used to classify burns by combining optical features from multispectral or hyperspectral imaging. Rather than employ models of light propagation to deduce tissue optical properties, we investigated the feasibility of using SFDI reflectance data at multiple spatial frequencies, with a support vector machine (SVM) classifier, to predict severity in a porcine model of graded burns. Calibrated reflectance images were collected using SFDI at eight wavelengths (471 to 851 nm) and five spatial frequencies (0 to 0.2 mm - 1). Three models were built from subsets of this initial dataset. The first subset included data taken at all wavelengths with the planar (0 mm - 1) spatial frequency, the second comprised data at all wavelengths and spatial frequencies, and the third used all collected data at values relative to unburned tissue. These data subsets were used to train and test cubic SVM models, and compared against burn status 28 days after injury. Model accuracy was established through leave-one-out cross-validation testing. The model based on images obtained at all wavelengths and spatial frequencies predicted burn severity at 24 h with 92.5% accuracy. The model composed of all values relative to unburned skin was 94.4% accurate. By comparison, the model that employed only planar illumination was 88.8% accurate. This investigation suggests that the combination of SFDI with machine learning has potential for accurately predicting burn severity.


Assuntos
Queimaduras/diagnóstico por imagem , Aprendizado de Máquina , Imagem Óptica/métodos , Algoritmos , Animais , Queimaduras/patologia , Calibragem , Cor , Luz , Óptica e Fotônica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Pele/patologia , Software , Máquina de Vetores de Suporte , Suínos , Cicatrização
9.
J Biomed Opt ; 24(2): 1-4, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30724041

RESUMO

Burn wounds and wound healing invoke several biological processes that may complicate the interpretation of spectral imaging data. Through analysis of spatial frequency domain spectroscopy data (450 to 1000 nm) obtained from longitudinal investigations using a graded porcine burn wound healing model, we have identified features in the absorption spectrum that appear to suggest the presence of hemoglobin breakdown products, e.g., methemoglobin. Our results show that the calculated concentrations of methemoglobin directly correlate with burn severity, 24 h after the injury. In addition, tissue parameters such as oxygenation (StO2) and water fraction may be underestimated by 20% and 78%, respectively, if methemoglobin is not included in the spectral analysis.


Assuntos
Queimaduras/diagnóstico por imagem , Hemoglobinas/química , Espectrofotometria/métodos , Algoritmos , Animais , Queimaduras/sangue , Modelos Animais de Doenças , Hemoglobinas/análise , Análise dos Mínimos Quadrados , Melaninas/química , Metemoglobina/química , Método de Monte Carlo , Imagem Óptica/métodos , Oxigênio/química , Oxiemoglobinas/química , Pele/metabolismo , Suínos , Água/química , Cicatrização
10.
Burns ; 45(2): 450-460, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30327232

RESUMO

While clinical examination is needed for burn severity diagnosis, several emerging technologies aim to quantify this process for added objectivity. Accurate assessments become easier after burn progression, but earlier assessments of partial thickness burn depth could lead to earlier excision and grafting and subsequent improved healing times, reduced rates of scarring/infection, and shorter hospital stays. Spatial Frequency Domain Imaging (SFDI), Laser Speckle Imaging (LSI) and thermal imaging are three non-invasive imaging modalities that have some diagnostic ability for noninvasive assessment of burn severity, but have not been compared in a controlled experiment. Here we tested the ability of these imaging techniques to assess the severity of histologically confirmed graded burns in a swine model. Controlled, graded burn wounds, 3cm in diameter were created on the dorsum of Yorkshire pigs (n=3, 45-55kg) using a custom-made burn tool that ensures consistent pressure has been employed by various burn research groups. For each pig, a total of 16 burn wounds were created on the dorsal side. Biopsies were taken for histological analysis to verify the severity of the burn. Clinical analysis, SFDI, LSI and thermal imaging were performed at 24 and 72h after burn to assess the accuracy of each imaging technique. In terms of diagnostic accuracy, using histology as a reference, SFDI (85%) and clinical analysis (83%) performed significantly better that LSI (75%) and thermography (73%) 24h after the burn. There was no statistically significant improvement from 24 to 72h across the different imaging modalities. These data indicate that these imaging modalities, and specifically SFDI, can be added to the burn clinicians' toolbox to aid in early assessment of burn severity.


Assuntos
Queimaduras/diagnóstico por imagem , Animais , Queimaduras/patologia , Fluxometria por Laser-Doppler , Imagem Óptica , Sus scrofa , Suínos , Termografia , Índices de Gravidade do Trauma
11.
Int Wound J ; 16(1): 144-152, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30273979

RESUMO

Major complications of diabetes lead to inflammation and oxidative stress, delayed wound healing, and persistent ulcers. The high morbidity, mortality rate, and associated costs of management suggest a need for non-invasive methods that will enable the early detection of at-risk tissue. We have compared the wound-healing process that occurs in streptozotocin (STZ)-treated diabetic rats with non-diabetic controls using contrast changes in colour photography (ie, Weber Contrast) and the non-invasive optical method Spatial Frequency Domain Imaging (SFDI). This technology can be used to quantify the structural and metabolic properties of in-vivo tissue by measuring oxyhaemoglobin concentration (HbO2 ), deoxyhaemoglobin concentration (Hb), and oxygen saturation (StO2 ) within the visible boundaries of each wound. We also evaluated the changes in inducible nitric oxide synthase (iNOS) in the dermis using immunohistochemistry. Contrast changes in colour photographs showed that diabetic rats healed at a slower rate in comparison with non-diabetic control, with the most significant change occurring at 7 days after the punch biopsy. We observed lower HbO2 , StO2 , and elevated Hb concentrations in the diabetic wounds. The iNOS level was higher in the dermis of the diabetic rats compared with the non-diabetic rats. Our results showed that, in diabetes, there is higher level of iNOS that can lead to an observed reduction in HbO2 levels. iNOS is linked to increased inflammation, leading to prolonged wound healing. Our results suggest that SFDI has potential as a non-invasive assessment of markers of wound-healing impairment.


Assuntos
Diabetes Mellitus Experimental/induzido quimicamente , Diabetes Mellitus Experimental/fisiopatologia , Imuno-Histoquímica/métodos , Fluxometria por Laser-Doppler/métodos , Estreptozocina/efeitos adversos , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/fisiopatologia , Animais , Masculino , Ratos , Cicatrização/fisiologia
12.
J Biomed Opt ; 23(3): 1-7, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29546735

RESUMO

Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by <4 % when accounting for motion artifact using the FM, which is less than the speckle contrast difference between superficial and full thickness burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.


Assuntos
Queimaduras/diagnóstico por imagem , Técnicas de Diagnóstico Cardiovascular , Processamento de Imagem Assistida por Computador/métodos , Animais , Artefatos , Movimento/fisiologia , Imagens de Fantasmas , Pele/diagnóstico por imagem , Suínos
13.
J Biomed Opt ; 22(7): 76013, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28727869

RESUMO

Tissue simulating phantoms can provide a valuable platform for quantitative evaluation of the performance of diffuse optical devices. While solid phantoms have been developed for applications related to characterizing exogenous fluorescence and intrinsic chromophores such as hemoglobin and melanin, we report the development of a poly(dimethylsiloxane) (PDMS) tissue phantom that mimics the spectral characteristics of tissue water. We have developed these phantoms to mimic different water fractions in tissue, with the purpose of testing new devices within the context of clinical applications such as burn wound triage. Compared to liquid phantoms, cured PDMS phantoms are easier to transport and use and have a longer usable life than gelatin-based phantoms. As silicone is hydrophobic, 9606 dye was used to mimic the optical absorption feature of water in the vicinity of 970 nm. Scattering properties are determined by adding titanium dioxide, which yields a wavelength-dependent scattering coefficient similar to that observed in tissue in the near-infrared. Phantom properties were characterized and validated using the techniques of inverse adding-doubling and spatial frequency domain imaging. Results presented here demonstrate that we can fabricate solid phantoms that can be used to simulate different water fractions


Assuntos
Diagnóstico por Imagem/métodos , Imagens de Fantasmas , Dispositivos Ópticos/normas , Óptica e Fotônica/normas , Silicones
14.
Lasers Surg Med ; 49(3): 293-304, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28220508

RESUMO

BACKGROUND AND OJECTIVES: The current standard for diagnosis of burn severity and subsequent wound healing is through clinical examination, which is highly subjective. Several new technologies are shifting focus to burn care in an attempt to help quantify not only burn depth but also the progress of healing. While accurate early assessment of partial thickness burns is critical for dictating the course of treatment, the ability to quantitatively monitor wound status over time is critical for understanding treatment efficacy. SFDI and LSI are both non-invasive imaging modalities that have been shown to have great diagnostic value for burn severity, but have yet to be tested over the course of wound healing. METHODS: In this study, a hairless rat model (n = 6, 300-450 g) was used with a four pronged comb to create four identical partial thickness burns (superficial n = 3 and deep n = 3) that were used to monitor wound healing over a 28 days period. Weekly biopsies were taken for histological analysis to verify wound progression. Both SFDI and LSI were performed weekly to track the evolution of hemodynamic (blood flow and oxygen saturation) and structural (reduced scattering coefficient) properties for the burns. RESULTS: LSI showed significant changes in blood flow from baseline to 220% in superficial and 165% in deep burns by day 7. In superficial burns, blood flow returned to baseline levels by day 28, but not for deep burns where blood flow remained elevated. Smaller increases in blood flow were also observed in the surrounding tissue over the same time period. Oxygen saturation values measured with SFDI showed a progressive increase from baseline values of 66-74% in superficial burns and 72% in deep burns by day 28. Additionally, SFDI showed significant decreases in the reduced scattering coefficient shortly after the burns were created. The scattering coefficient progressively decreased in the wound area, but returned towards baseline conditions at the end of the 28 days period. Scattering changes in the surrounding tissue remained constant despite the presence of hemodynamic changes. CONCLUSIONS: Here, we show that LSI and SFDI are capable of monitoring changes in hemodynamic and scattering properties in burn wounds over a 28 days period. These results highlight the potential insights that can be gained by using non-invasive imaging technologies to study wound healing. Further development of these technologies could be revolutionary for wound monitoring and studying the efficacy of different treatments. Lasers Surg. Med. 49:293-304, 2017. © 2017 Wiley Periodicals, Inc.


Assuntos
Queimaduras/diagnóstico por imagem , Queimaduras/patologia , Fluxometria por Laser-Doppler/métodos , Cicatrização/fisiologia , Animais , Biópsia por Agulha , Modelos Animais de Doenças , Estudos de Avaliação como Assunto , Imuno-Histoquímica , Escala de Gravidade do Ferimento , Masculino , Consumo de Oxigênio/fisiologia , Fotografação , Distribuição Aleatória , Ratos , Ratos Pelados , Fluxo Sanguíneo Regional/fisiologia , Pigmentação da Pele , Fatores de Tempo
15.
Burns ; 41(6): 1242-52, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26138371

RESUMO

Surgical intervention of second degree burns is often delayed because of the difficulty in visual diagnosis, which increases the risk of scarring and infection. Non-invasive metrics have shown promise in accurately assessing burn depth. Here, we examine the use of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) for predicting burn depth. Contact burn wounds of increasing severity were created on the dorsum of a Yorkshire pig, and wounds were imaged with SFDI/LSI starting immediately after-burn and then daily for the next 4 days. In addition, on each day the burn wounds were biopsied for histological analysis of burn depth, defined by collagen coagulation, apoptosis, and adnexal/vascular necrosis. Histological results show that collagen coagulation progressed from day 0 to day 1, and then stabilized. Results of burn wound imaging using non-invasive techniques were able to produce metrics that correlate to different predictors of burn depth. Collagen coagulation and apoptosis correlated with SFDI scattering coefficient parameter [Formula: see text] and adnexal/vascular necrosis on the day of burn correlated with blood flow determined by LSI. Therefore, incorporation of SFDI scattering coefficient and blood flow determined by LSI may provide an algorithm for accurate assessment of the severity of burn wounds in real time.


Assuntos
Apoptose , Queimaduras/diagnóstico , Fluxometria por Laser-Doppler/métodos , Necrose/patologia , Imagem Óptica/métodos , Pele/patologia , Animais , Queimaduras/patologia , Modelos Animais de Doenças , Feminino , Pele/irrigação sanguínea , Análise Espacial , Sus scrofa , Suínos , Índices de Gravidade do Trauma
16.
J Surg Res ; 197(1): 210-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25935469

RESUMO

BACKGROUND: Detecting failing tissue flaps before they are clinically apparent has the potential to improve postoperative flap management and salvage rates. This study demonstrates a model to quantitatively compare clinical appearance, as recorded via digital camera, with spatial frequency domain imaging (SFDI), a noninvasive imaging technique using patterned illumination to generate images of total hemoglobin and tissue oxygen saturation (stO2). METHODS: Using a swine pedicle model in which blood flow was carefully controlled with occlusion cuffs and monitored with ultrasound probes, throughput was reduced by 25%, 50%, 75%, and 100% of baseline values in either the artery or the vein of each of the flaps. The color changes recorded by a digital camera were quantified to predict which occlusion levels were visible to the human eye. SFDI was also used to quantify the changes in physiological parameters including total hemoglobin and oxygen saturation associated with each occlusion. RESULTS: There were no statistically significant changes in color above the noticeable perception levels associated with human vision during any of the occlusion levels. However, there were statistically significant changes in total hemoglobin and stO2 levels detected at the 50%, 75%, and 100% occlusion levels for arterial and venous occlusions. CONCLUSIONS: As demonstrated by the color imaging data, visual flap changes are difficult to detect until significant occlusion has occurred. SFDI is capable of detecting changes in total hemoglobin and stO2 as a result of partial occlusions before they are perceivable, thereby potentially improving response times and salvage rates.


Assuntos
Percepção de Cores , Retalhos de Tecido Biológico/irrigação sanguínea , Imagem Óptica , Fotografação , Animais , Biomarcadores/sangue , Retalhos de Tecido Biológico/fisiologia , Hemoglobinas/metabolismo , Oxigênio/sangue , Suínos
17.
Burns ; 41(5): 1058-63, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25814299

RESUMO

A critical need exists for a robust method that enables early discrimination between superficial-partial and deep-partial thickness burn wounds. In this study, we report on the use of laser speckle imaging (LSI), a simple, non-invasive, optical imaging modality, to measure acute blood flow dynamics in a preclinical burn model. We used a heated brass comb to induce burns of varying severity to nine rats and collected raw speckle reflectance images over the course of three hours after burn. We induced a total of 12 superficial-partial and 18 deep-partial thickness burn wounds. At 3h after burn we observed a 28% and 44% decrease in measured blood flow for superficial-partial and deep-partial thickness burns, respectively, and that these reductions were significantly different (p=0.00007). This preliminary data suggests the potential role of LSI in the clinical management of burn wounds.


Assuntos
Queimaduras/patologia , Pele/patologia , Animais , Queimaduras/diagnóstico , Modelos Animais de Doenças , Fluxometria por Laser-Doppler , Masculino , Ratos , Ratos Sprague-Dawley , Pele/irrigação sanguínea
18.
Neurophotonics ; 2(4): 045001, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26835482

RESUMO

Baseline optical properties are typically assumed in calculating the differential pathlength factor (DPF) of mouse brains, a value used in the modified Beer-Lambert law to characterize an evoked stimulus response. We used spatial frequency domain imaging to measure in vivo baseline optical properties in 20-month-old control ([Formula: see text]) and triple transgenic APP/PS1/tau (3xTg-AD) ([Formula: see text]) mouse brains. Average [Formula: see text] for control and 3xTg-AD mice was [Formula: see text] and [Formula: see text], respectively, at 460 nm; and [Formula: see text] and [Formula: see text], respectively, at 530 nm. Average [Formula: see text] for control and 3xTg-AD mice was [Formula: see text] and [Formula: see text], respectively, at 460 nm; and [Formula: see text] and [Formula: see text], respectively, at 530 nm. The calculated DPF for control and 3xTg-AD mice was [Formula: see text] and [Formula: see text] OD mm, respectively, at 460 nm; and [Formula: see text] and [Formula: see text] OD mm, respectively, at 530 nm. In hindpaw stimulation experiments, the hemodynamic increase in brain tissue concentration of oxyhemoglobin was threefold larger and two times longer in the control mice compared to 3xTg-AD mice. Furthermore, the washout of deoxyhemoglobin from increased brain perfusion was seven times larger in controls compared to 3xTg-AD mice ([Formula: see text]).

19.
Biomed Opt Express ; 5(10): 3467-81, 2014 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-25360365

RESUMO

Accurate and timely assessment of burn wound severity is a critical component of wound management and has implications related to course of treatment. While most superficial burns and full thickness burns are easily diagnosed through visual inspection, burns that fall between these extremes are challenging to classify based on clinical appearance. Because of this, appropriate burn management may be delayed, increasing the risk of scarring and infection. Here we present an investigation that employs spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) as non-invasive technologies to characterize in-vivo burn severity. We used SFDI and LSI to investigate controlled burn wounds of graded severity in a Yorkshire pig model. Burn wounds were imaged starting at one hour after the initial injury and daily at approximately 24, 48 and 72 hours post burn. Biopsies were taken on each day in order to correlate the imaging data to the extent of burn damage as indicated via histological analysis. Changes in reduced scattering coefficient and blood flow could be used to categorize burn severity as soon as one hour after the burn injury. The results of this study suggest that SFDI and LSI information have the potential to provide useful metrics for quantifying the extent and severity of burn injuries.

20.
J Biomed Opt ; 18(9): 096007, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24005154

RESUMO

There is a need for cost effective, quantitative tissue spectroscopy and imaging systems in clinical diagnostics and pre-clinical biomedical research. A platform that utilizes a commercially available light-emitting diode (LED) based projector, cameras, and scaled Monte Carlo model for calculating tissue optical properties is presented. These components are put together to perform spatial frequency domain imaging (SFDI), a model-based reflectance technique that measures and maps absorption coefficients (µa) and reduced scattering coefficients (µs') in thick tissue such as skin or brain. We validate the performance of the flexible LED and modulation element (FLaME) system at 460, 530, and 632 nm across a range of physiologically relevant µa values (0.07 to 1.5 mm-1) in tissue-simulating intralipid phantoms, showing an overall accuracy within 11% of spectrophotometer values for µa and 3% for µs'. Comparison of oxy- and total hemoglobin fits between the FLaME system and a spectrophotometer (450 to 1000 nm) is differed by 3%. Finally, we acquire optical property maps of a mouse brain in vivo with and without an overlying saline well. These results demonstrate the potential of FLaME to perform tissue optical property mapping in visible spectral regions and highlight how the optical clearing effect of saline is correlated to a decrease in µs' of the skull.


Assuntos
Diagnóstico por Imagem/métodos , Absorção , Animais , Encéfalo/anatomia & histologia , Encéfalo/irrigação sanguínea , Hemoglobinas/análise , Processamento de Imagem Assistida por Computador , Camundongos , Camundongos Endogâmicos C57BL , Método de Monte Carlo , Oxiemoglobinas/análise , Imagens de Fantasmas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...